◆PVC-U pipe
is applicable for the transportation
of liquids no more than 45℃.
◆Pressure
grade over1.0Mpa PVC-U pipes should
be adopt inside the building pressure
pipes and use the special adhesive provided
by the company.
◆The pipes
should be concealing buried or take
relative protection methods in the places
may be often collided places.
◆While
the PVC-U pressure pipe is buried in
the outdoor exposing places and freezing
basements,the light weight materiall
should be adopted in the freezing or
sunlight irradiation places to thermal
insulation and heat preservation.
◆PVC-U
pressure pipe should be buried far away
from heat.
◆PVC-U
pipe desige flow rate shall not be over
1.5m/s,normally13m/s.
◆The flow
velocity should≤2m/s while washing the
PVC-U pipes.
◆Tt is
strictly prohibited to be stroked,thrown,fallen,rolled
and dragged,and collide with the shape
objects in transporting,loading and
unloading and storage the PVC-U pipes.It
also should avoid sludge oil and sunlight
irradiation.The stock place should be
flat and tide .The expansion end of
the flared pipe should be alternately
stocked to avoid distortion.
◆The adhesive
joint should not be constructed under
5℃,and the rubber ring joint should
not be constructed under -10℃,The adhesive
construction site is strictly prohibited
from fire.
●The
inserting length should accord with
the stipulations in the following table
while the pipe adopts the rubber ring
joint(R-R joint)
| Nominal
outside diameter(mm) |
63 |
75 |
90 |
110 |
125 |
140 |
160 |
200 |
225 |
250 |
315 |
355 |
400 |
500 |
| Inserting
length(mm) |
110 |
120 |
130 |
130 |
140 |
145 |
150 |
170 |
190 |
200 |
230 |
250 |
270 |
285 |
●See
the following table for the standing solidifying
time while adopting the adhesive jojnt
(T-S joint).
|
Nominal outside diameter(mm) |
Surface temperature on piping
|
|
18℃-40℃ |
5℃-18℃ |
|
≤50 |
20 |
30 |
|
63-90 |
45 |
60 |
◆The adhesive
with color changed,agglomeration and deposition
should be prohibited to be used.
◆The pipes
and appearance of the pares must be checked
in installing and using. The broken and